Sie befinden sich hier: Startseite » Produkte » XCS-T1000 Ex Climatic Test Cabinet

XCS-T1000 Ex Climatic Test Cabinet

Product Information

  • Temperature 0 °C to +35 °C, optionally -20°C to +80 °C
  • Humidity Range 20 to 80 % r. h.
  • Test Room 1000 Litres
  • Test Room Explosion-proof for Zone 1 and 2
  • EC Type examination according to Directives 2014/34/EC
  • Program Controller Control2015touch
  • Screen Recorder and USB/Ethernet
TypeXCS-T1000
Test Room
Volume1000 l
Temperature Range0°C to +35 °C, optionally -20°C to+80°C
Humidity Range20 to 80 %
Deviation in Time±0,5 °C / ±2% rel. F.
Height1500 mm
Width2 x 610 mm
Depth585 mm
Number of shelves8
Maximum load per shelf25 kg
Appliance
Height2105 mm
Width1520 mm
Depth1060 mm
Electr. Connection230 V / 50 Hz
Net weight of the standard unit300 kg
Refrigerant
Type / GWPR290 / 3
CO2-Equivalent0,0008 t

Enquiry Questionnaire

Please choose the options, which are relevant for the product enquiry.

Temperature Options

test

Extension of the minimum temperature to -20 °C.

test

Extension of the maximum temperature to +80 °C. Unit depth in this case +225 mm. Electr. Connection 400/230 V/50 Hz

test

Augmentation of the speed of temperature change to 1 °C/min in the temperature range of 0 °C to +35 °C.

test

Augmentation of the speed of temperature change to 1 °C/min in the temperature range of -20°C to +80°C.

Humidity Options

Ion exchanger for direct connection to the drinking water pipe, if demineralized water supply is not available.

Canister for water supply at installation places without water connection.

Optional Accessories

Their maximum carrying capacity is up to 25 kg.

The reinforced stainless-steel grid shelves are recommendable for building material testing or beer forced-ageing tests. Their maximum carrying capacity is up to 50 kg.

Their maximum carrying capacity is up to 50 kg. The reinforced stainless-steel grid shelves are recommendable for building material testing or beer forced-ageing tests.

The triple glazed glass panel door always ensures an optimum view into the test room.

A 45 mm duct in the lateral panel allows insertion of measuring lines and hoses into the test room. Delivery including cover.

Gas-tight closing plug, matching to the tubular port. The gasket system with a flexibility in the range of 4 mm to 23 mm is based on a rubber module with removable skins and can be adapted to the cables, tubes etc. in different sizes.

Mobile version of the test cabinet with 4 steering rollers, 2 of them lock-type with brake.

Collecting pan for dew water or condensate. It can be easily withdrawn to the front.

Export execution for power supply 110 V/60 Hz.

Communication and Software

Analogue output test room temperature for external recorder Signal 0-10 V, 0-20 mA, 4-20 mA

Analogue output test room humidity for external recorder Signal 0-10 V, 0-20 mA, 4-20 mA

- Monitoring of up to 32 appliances   - Compatible with Control 2000 and Control2015 touch   - Data logging and graph representation   - Logging of door openings with time stamp   - Logging of alarms with time stamp   - Automated daily print is possible   - Weekly and monthly print   - Archiving per day and control circuit   - Automated backup on server drive  

- Monitoring of appliances with Control2015 touch - Data safety in conformity with the guidelines 21CFR Part 11 - All events are recorded in a digital logbook, inseparably connected with the recorded data. - Signature in connection with the user management of the appliances - Automated prints  - Automated backup on server drive

Calibration and Qualification

Calibration on site with 9 spatially distributed sensors with a temperature value.

Calibration on site with 9 spatially distributed sensors with a temperature/humidity value.

Calibration on site with 9 spatially distributed sensors with a temperature value.

Calibration on site with 9 spatially distributed sensors with a temperature/humidity value.

We are always ready to support the validation of your appliances. If desired, the validation can be executed by our company. The validation includes the necessary measurements, as well as any documents, such as DQ, IQ, OQ and PQ, manuals, wiring diagrams, plans, appliance logbook, manufacturer certificates for the sensors and for the most important components. If required, we are also at your disposal for the annual recalibration.

Execution and documentation of the design qualification, qualification of installation and operation qualification including calibration on site with 9 spatially distributed sensors with a temperature value on site.

Execution and documentation of the design qualification, qualification of installation and operation qualification including calibration on site with 9 spatially distributed sensors with a temperature/humidity value on site.

Execution and documentation of the performance qualification including calibration on site with 9 spatially distributed sensors with a temperature value on site.

Execution and documentation of the performance qualification including calibration on site with 9 spatially distributed sensors with a temperature/humidity value on site.

    Title*

    Academic Title

    First Name*

    Surname*

    Company / Institute*

    Department

    Street*

    House Number*

    ZIP*

    City*

    Country*

    E-Mail-Adress*

    Phone*

    Newsletter

    Yes, I want to receive RUMED's free newsletter. I can unsubscribe easily at any time.

    Request catalogue

    Subject

    Info

    Please enter the unit type (1) and the serial number (2) into the enquiry form.

    BUnit type and serial number of the Control 2000 are displayed after actuation of the key i.

    Your Message